Digital Mammography: Computer-assisted Diagnosis Method for Mass Detection with Multiorientation and Multiresolution Wavelet Transforms

LH Li,W Qian,LP Clarke
DOI: https://doi.org/10.1016/s1076-6332(97)80075-x
IF: 5.482
1997-01-01
Academic Radiology
Abstract:Rationale and Objectives. The authors evaluated a modular computer-assisted diagnosis (CAD) method for mass detection that uses computation of features in three domains (gray level, morphology, and directional texture). Their objectives were to improve the sensitivity of detection and reduce the false-positive (FP) detection rate.Materials and Methods. The directional wavelet transform (DWT) method, which uses both multiorientation and multiresolution wavelet transforms to improve image preprocessing and segmentation of suspicious areas and to extract both morphologic and directional texture features, was evaluated with a previously reported image database containing 50 normal and 45 abnormal digitized screen-film mammograms. The mammograms contained all mass types and included 16 minimal cancers. This method was compared with the Markov random field (MRF) method to avoid issues related to case selection criteria. Free-response receiver operating charcteristic curves were compared to both DWT and MRF methods.Results. For the DWT method, the sensitivity was 98% and the FP detection rate was 1.8 FP findings per image. For the MRF method, sensitivity was 90% and the FP detection rate was 2.0 FP findings per image.
What problem does this paper attempt to address?