Abstract:The transducer frequency,aperture,element size,focus length and scanning angle have great impact on the focus of phased array beam,the relationship and restriction among those parameters are complicated.An experimental study on the influence of beam focus for the image quality is carried out use a 60 elements linear array transducer based on the beam focus principle.The A-scan echo amplitudes of 3 horizontal holes are measured respectively,with the focus length of 5mm~80mm and array aperture of 5mm~30mm.The analysis on the optimal match method between the focus length and aperture has demonstrated the essentiality of parameter optimization.The results are of great value to the application of phased array ultrasonic testing.