3D simulation method for endovascular intervention

Zhou Zhengdong,Luo Limin
DOI: https://doi.org/10.3969/j.issn.1001-0505.2010.02.023
2010-01-01
Abstract:To overcome the limitation of modeling and collision cancellation in endovascular intervention simulation,a multibody-bilayer model representing the combination of guide catheter and guide wire is proposed,and a fast collision cancellation algorithm based on geometric analysis and angular propagation is put forward. A 3D real time simulation system is developed for the evaluation of the behavior of guide catheter-wire combination inside specific patient vasculature.The multibody-bilayer model is considered as a chain of many segments.Each segment represents a segment of guide wire or catheter or both.The guide wire and catheter are defined with different radius,different properties,but with the same length for each segment.The motion of guide wire and catheter inside vascular is guided by the collision detection and collision cancellation algorithm. A relaxation procedure is applied to the model to achieve more realistic status when the model arrives at the target location.The experimental results show that the behavior of the guide catheter-wire combination inside vasculature depends on the defined material parameters,and real time simulation can be achieved.The simulation system is effective and promising in clinical application.
What problem does this paper attempt to address?