Effect of Fenton process on leachate pre-treated by biological process and pH regulation

Zha Er,Zhu Nanwen,Tu Xingyu,Lou Ziyang
2010-01-01
Abstract:Leachate from Laogang Refuse Landfill was processed by Fenton reagent after it was pre-treated by anaerobic filter and aerobic biological process and pH regulation with CaO in this work.It was found that COD and TP could be removed by 24% and 25%,respectively after leachate was pre-treated by anaerobic filter/aerobic biological process,and the removal rate of COD and TP could be further increased to 42% and 96%,respectively after the pH value of leachate was adjusted to 12 using CaO.Then,Fenton process was introduced to remove the remained pollutant in leachate,and the effect of molar ratio of Fe2+ and H2O2,pH,H2O2 dosage,reaction time and feeding mode on COD removal efficiency were investigated.Results showed that the optimum operation conditions were pH of 2,H2O2/Fe2+ of 5∶1(molar ratio),H2O2 dosage of 2.4 g/L and the reaction time of 2 h.Under the above conditions,the COD of leachate was reduced from 1 340 mg/L to 198 mg/L,with a total removal rate of 85%.
What problem does this paper attempt to address?