Determination of Poly Brominated Diphenyl Ethers in Newborn Umbilical Cord Blood by Solid-phase Extraction and Gas Chromatography-mass Spectrometry

Qiong-na XIAO,Xia HUO,Yuan-ping WANG,Ku-sheng WU,Yong-yong GUO,Xi-jin XU
2011-01-01
Abstract:Objective:To improve the analytical method of the poly brominated diphenyl ethers(PBDEs)in newborn umbilical cord blood.Method:The formic acid and acetonitrile were added in 2 mL serum,vortexed and ultrasonic processed.The mixture was extracted by solid-phase extraction and cleaned-up with a silica/sulfuric acid column.Samples were analyzed by gas chromatograph-mass spectrometry(GC-MS)with negative chemical ionization,operated in selected ion monitoring mode and external standard method for quantification of PBDEs.Results: The concentration had a good linear range(0.5~32.0 ng/mL),the correlation coefficient was above 0.997.The average recovery of the internal standard was from 80.0% to 110.0%.The detection limit of the method was within range of 0.01 to 0.07 ng/g.The average recovery of the samples and the relative standard deviation of the method were 86.4%~93.7% and 5.3%~9.8% respectively.Conclusion: Determination of PBDEs in newborn umbilical cord blood by solid-phase extraction and GC-MS.This method is fast、sensitive,high reproducible with satisfied recoveries.
What problem does this paper attempt to address?