Determination of Astragaloside Ⅳ in Ejiao Buxue Koufuye by HPLC-ELSD

刘同祥,尚宝昌,陈富君,王继蜂
DOI: https://doi.org/10.3969/j.issn.1005-5304.2007.05.022
2007-01-01
Abstract:Objective To establish a method for the determination of AstragalosideⅣin Ejiao Buxue Koufuye.Methods HPLC-ELSD was used to determine directly AstragalosideⅣin Ejiao Buxue Koufuye on Betasil C_(18) column,using CH_3OH-H_2O(74:26)as a mobile phase.The flow rate was 1.0mL/min.The temperature of drift tube for ELSD was 90℃and the flow rate of N_2 was 2.0L/min.Results The linear range of AstragalosideⅣwas 0.43~2.15μg,Y=1.53637X+0.92158,r=0.9999(n=6),the average recovery of the added sample was 98.5% and RSD=0.98%.Conclusion The method is accurate and reliable with a good reproducibility.It can be used for the quality control of Ejiao Buxue Koufuye.
What problem does this paper attempt to address?