Application of Simulated Jaw Model in the Oral Implantology Combining with Three-dimensional Laser Scanning Technology

许卫华,唐志辉,吴敏节,赵雪竹,朱洁
DOI: https://doi.org/10.13701/j.cnki.kqyxyj.2011.06.018
2011-01-01
Abstract:Objective: To create an accurate jaw model with three-dimensional laser scanning technology.Methods: Twenty patients implant denture in the second center of Peking University Stomatological Hospital were included in this study.All patients accepted comprehensive and careful examination of oral cone beam CT scanning and had full mouth dentition impression.The cone beam CT scanning data of each patient and 3D laser scanning data of patient's dentition plaster model matched with three-dimensional targeting computer software to form three-dimensional computer model of jaw.And the final three-dimensional jaw model was formed by three-dimensional rapid prototyping machine.Results: Twelve of twenty patients with jaw of cone-beam CT data and 3D laser scanning data matched accurately;Surgical and rehabilitation planning and surgical guides were well designed and manufactured in these models;Implant operation and the final restoration were successfully performed with the guiding of the operation guide.Matching of CBCT data with laser scan model found CBCT deviation in the posterior area in three of 20 patients with the maximum deviation of 1mm.There were five cases showing discrepancies of bone morphology between the models and the real clinical condition,and the bone defects were larger in the models.Conclusion: The accuracy of three-dimensional jaw model formed by combing CT scan data with laser scanning techniques has significantly improved.