PINHOLE IMAGING CALCULATED BY MCNP CODE

Chen Faxin,Zheng Jian,Li Zhenghong
DOI: https://doi.org/10.3969/j.issn.1000-386X.2010.07.055
2010-01-01
Abstract:Pinhole imaging of neutron or gamma is applied broadly in many researching areas.Thick pinhole collimator is needed generally,as the two kinds of radiation have quite strong penetration ability,so that the effects of scattering and penetrating must be considered when computing pinhole imaging.Pinhole imaging calculation is very difficult on account of computing particles transmission in all kinds of materials.Therefore Monte Carlo N-Particle(MCNP) transport code which is a general-purpose particle transmission program is used to compute pinhole imaging.In this paper the performances of four methods in MCNP are discussed detailedly,the variance reduction techniques and physical modelling skills computed with these methods are also described.
What problem does this paper attempt to address?