Optimization of the HPLC Fingerprint for Cornus Officinalis
YANG Ning,LIU Yan-ni,KANG Jie-fang
DOI: https://doi.org/10.16155/j.0254-1793.2014.11.014
2014-01-01
Abstract:Objective: To optimize the fingerprint of Cornus officinalis using HPLC technology. Methods: The Phenomenex C18column( 250 mm × 4. 6 mm,5 μm) and the diode array detector( DAD) were used for separation and detection,respectively. The separation process was carried out using a gradient elution( 0- 15 min,2 %B→4 % B; 15- 50 min,4 % B →16 % B; 50- 57 min,16 % B →18 % B; 57- 67 min,18 % B →25 % B; 67- 87 min,25 % B→90 % B; 87- 95 min,90 % B),which was based on a mobile phase of the mixture aqueous solution with 0. 1 % formic acid( A)- acetonitrile( B) at the flow rate of 1. 0 m L·min- 1. The detection wavelength was260 nm,and the column temperature was 30 ℃. The chromatographic fingerprints were analyzed with the similarity evaluation system for chromatographic fingerprint of TCM( 2004 A edition). Results: Totally 19 common fingerprint peaks and 7 constituents including morroniside,loganin,sweroside,cornuside,gallic acid,5- hydroxymethyl furfural( 5- HMF) and protocatechuic acid were identified after optimization of the detection wavelength,mobile phase and HPLC chromatography gradient elution conditions. Furthermore,the similarity of HPLC fingerprints of 11 different batches of Cornus officinalis was high,being over 0. 9. Conclusion: The present methodology meets the technical requirements of fingerprint and could be a basis for the intrinsic quality control standard for Cornus officinalis.