Development and Test of 5 MPa High Pressure Proton Exchange Membrane Water Electrolysis System

Zhou Kanghan,Ren Chunbo,Wang Fei,Li Junrong,Zhang Liyan
DOI: https://doi.org/10.16289/j.cnki.1002-0837.2012.05.016
2012-01-01
Abstract:Objective To realize the engineering of proton exchange membrane(PEM) water electrolysis technology and satisfy the engineering application.Methods Based on the high current density membrane electrode,engineering design was carried out for the flow diagram and operating pressure of the PEM water electrolysis system.A high pressure water electrolysis system was manufactured with single electrolyzer which could produce 3000 L O2 per hour.Electrochemical performance of the high pressure PEM water electrolysis system was tested.The influence of operating pressure on parameters such as current density,electrolysis voltage,gas purity and electrolysis efficiency were studied.Results The high pressure water electrolysis system could stably output oxygen at 5 MPa pressure with the purity greater than 99.5%.The cell voltage was less than 1.9 V at 1.0~1.3 A/cm2.Conclusion The high pressure PEM water electrolysis system can meet the requirement of practical application.
What problem does this paper attempt to address?