Study on Stator Slot Wedge Based on Plank Model and Its Characteristic Parameters

Deng Y,Jia Z,Xia Y,Peng X,Guan Z,Wang L.
DOI: https://doi.org/10.13334/j.0258-8013.pcsee.2011.27.011
2011-01-01
Abstract:Stator bar is excited by 100 Hz electromagnetic force in generators during operation,leading to serious vibration,so the bars are usually fixed within stator slot via ripple spring and wedge.However,stator wedges are becoming loose during long period of vibration,which will accelerate the deterioration of stator bar main insulation even lead to power outage.So it's of vital importance to detect the looseness of stator wedge for the security of power systems.This paper is concerned with the relationship among vibration characteristics of stator wedge,ripples spring deformation and excitation force,which identify the looseness of wedge tighting system,and also first present the plank model,which was verified by looseness detection experiments.According to mathematic analysis,the condition of wedge tighting system can be effectively reflected by the first maximum amplitude.First maximum amplitude decreases as deformation of ripple spring grows,while measuring sensitivity can be improved by higher excitation force.
What problem does this paper attempt to address?