Determination of the Plasma Concentration of 10-Hydroxycamptothecin in Mice by RP-HPLC

GUO Hong-hong,ZHENG Jian,JING Li-jia,LI Si-yang,YAN Xiu-feng,WANG Yang
2011-01-01
Abstract:OBJECTIVE:To establish the method for the concentration determination of 10-hydroxycamptothecin(HCPT)in mice plasma.METHODS:33 mice were given HCPT 80 mg·kg -1 intragastrically.The blood samples of heart were collected before administration and 0.17 h,0.33 h,0.67 h,1 h,1.5 h,2 h,4 h,8 h,12 h,24 h after administration.The plasma concentration of HCPT was determined on Luna C18 column with mobile phase consisted of water-methanol(gradient elution)at the flow rate of 1.2 mL·min-1 .Fluorescence detector with excitation and emission wavelengths of 383 nm and 553 nm was used for the determination of HCPT.Camptothecin was used as internal standard.RESULTS:Endogenous impurity did not interfere with the determination. The linear range of HCPT were 1.25~80 ng·mL-1 (r=0.999 7).The average assay recovery was 96.46%~101.87% and extraction recovery was 82.4%~109.6%.The intra-day and inter-day precision were less than 5.00%.CONCLUSION:The method is simple,reliable,specific and sensitive.It is suitable for plasma concentration of HCPT.