The Selection and Compatibility Indoor Study of Scale Inhibitor and Corrosion Inhibitor Used in Oilfield

张银,樊泽霞,张亮,任韶然,马莹
DOI: https://doi.org/10.3969/j.issn.1674-8980.2008.03.018
2008-01-01
Abstract:This dissertation is aimed at studying the corrosion and scale problems in produced water systems of oilfields.An electro-chemical corrosion meter,CMB-4510A,is used to measure corrosion rate.The coupon method is also used,along with the electrochemical technique,to provide reliable corrosion rate estimation.The titration method has been performed to assess scale inhibitors,and the compatibility of corrosion and scale inhibitor has been studied.The results reveal that 956 and FHH-02 corrosion inhibitors have better effects,and the results demonstrate that 1320C and BHF-06 scale inhibitors have ideal effects.The compatibility of 1320C and FHH-02 is better,and the combination of 1320C and 956,FHH-02 has an ideal effect.
What problem does this paper attempt to address?