The Effect of Different Surface Processing of BLB Implants on Osseointegration

ZHU Zhen-kun,SHAO Shan,LAN Jing,XU Xin
2009-01-01
Abstract:PURPOSE: To evaluate the effect of different surface processing of BLB implants on osseointegration. METHODS: Six Beagle dogs,thirty-six implants with different surface processing were divided into 2 groups (A:18 BLB Ⅲ implants with HA+SLA surface processing ;B:18 BLBⅠimplant with HA surface processing). Three BLBⅠand 3 BLB Ⅲ were placed into the mandible of each Beagle dog immediately and randomly at the 2nd, 3th, 4th pre-molars which were extracted under anesthesia. At the 2nd, 4th, 8th week after operation, two Beagles dogs were sacrificed,respectively. The specimen were observed by gross examination, histological examination, ground section of bone with implant. RESULTS: At the 2nd, 4th week, the bone contact rate of BLBⅢ group was significantly higher than that of BLBⅠgroup (P0.05). At the 8th week, there was no significant difference between two groups. CONCLUSION: BLBⅢ shows considerable positive effect on osseointegration to implants in a short-time, but it’s not obvious after 8 weeks.