The column experimental study of nanoscale iron-microorganisms in water nitrate removal system

Zhao Qianqian,Li Tielong,Jin Zhaohui,An Yi,Dong Meiying
DOI: https://doi.org/10.3969/j.issn.2095-2783.2010.05.003
2010-01-01
Abstract:Column tests were carried out for nitrate removal by a nano iron-microbial system. The effects of such factores as nano-iron dose,cultivation pattern,and hydraulic retention time on the nitrate removal efficiency and the products.were studied. Results showed that with the amount of nano-iron increased from 0.056 g to 0.280 g in the system,nitrate removal rate increased from 35% to 90% and the amount of ammonia produced in the volume increased from 3.059 mg/L to 11.692 mg/L,respectively. The effect was even better when the nano-iron and microbial was placed and cultivated in the incubator at 26 ℃ for 5days than that without cultivation. In addition,the nitrate removal rate increased when the hydraulic retention time extended from 0.50 h to 2.01 h.
What problem does this paper attempt to address?