Research and Optimization on Ground Heat Exchanger Predictive Model

Wen-jie GANG,Jin-bo WANG
DOI: https://doi.org/10.3969/j.issn.1002-8528.2011.12.019
2011-01-01
Building Science
Abstract:For hybrid ground source heat pump system(HGSHPS),control strategy could be optimized to a large extent.In this paper,a new control strategy of comparing the outlet water temperatures of ground heat exchanger(GHE) and cooling tower was proposed,and an accurate predictive model was established.Firstly,in order to improve the prediction accuracy,the established models were divided into two types,the static model taken variables of current moment as inputs,and the dynamic model taken variables of both current and former moments as inputs.And then,a series of models were built to validate the feasibility and accuracy of artificial neural network(ANN) model under different operation modes of HGSHPS,and the simulation results were compared with those of the dynamic model.The results shown that ANN model could accurately predict the outlet water temperature of GHE no matter what operation mode of HGSHPS was.Furthermore,the dynamic model could obtain higher accuracy than ANN model with the absolute error less than 0.2 ℃.