Tubridge Flow Diverter or in Combination with Coils for Treatment of Large or Giant Anterior Circulation Aneurysms:A Follow-Up Observation

ZHOU Yu,YANG Peng-fei,HUANG Qing-hai,XU Yi,HONG Bo,ZHAO Wen-yuan,LI Qiang,FANG Yi-bin,ZHAO Rui,YANG Zhi-gang,LIU Jian-min
DOI: https://doi.org/10.3969/j.issn.1672-5921.2013.10.003
2013-01-01
Abstract:Objective To evaluate the safety and efficacy of Tubridge flow diverter( FD) in the treatment of large or giant intracranial anterior circulation aneurysms. Methods Twenty-eight patients treated with Tubridge FD from August 2010 to August 2012 were retrospectively collected and analyzed.The clinical data and follow-up results of 28 unruptured saccular wide-necked intracranial aneurysms on the internal carotid arteries were obtained. Results ①The size of 28 aneurysms in this group was 11. 3-44. 0 mm( mean 21. 6 ± 7. 1 mm). A total of 33 Tubridge FD were implanted. All the Tubridge FDs were successfully implanted except one failed to fully open. ②Of the 28 aneurysms,18 were packed with coils.The immediate embolization results were graded according to Raymond grade. Two patients had residual aneurysm neck,16 were mostly embolized; and 10 aneurysms were only treated with stents. After stenting,angiography showed that the filling mode of all aneurysmal contrast agents changed. Contrast agent retention within the aneurysms was observed. Aneurysm filling volumes of 7 patients were significantly reduced after the procedure( the reduced filling ratios in 5 patients were 0 to 50% and in 2 were ≥ 50%). During the treatment,no procedure-related hemorrhagic or ischemic events occurred in this group. ③In the clinical follow-up process( 6 to 30 months,mean 19. 0 months),transient clinical symptoms aggravated in 5 patients; at the last follow-up,the symptoms of 13 patients were relieved,6 were improved,and 4 were stable. ④ After the procedure,25 aneurysms were followed up with DSA( 5 to 24 months,mean 9. 9months),18 of them were cured with aneurysm imaging( 72%),6 were improved( 24%,only a few residual aneurysm necks),and one was stable( 4%); the branch arteries covered by stents still remained patent. No in-stent restenosis and parent artery occlusion occurred. Conclusion Tubridge FD is safe and effective in the treatment of large and giant intracranial anterior circulation aneurysms. However,the data in this group is only the single center follow up results. The long term efficacy remains to be confirmed by a prospective multicenter controlled study.
What problem does this paper attempt to address?