Effect of Rotor Angle Deviation on Stability of Doubly-Fed Induction Generator-Based Wind Power Generation System

WANG Zhong,LI Guojie,SUN Yuanzhang,HUANG Xiaohui
2010-01-01
Abstract:Stability of control system is of crucial importance to reliable operation of wind power generation system.Vector control is the most popular control strategy used in doubly-fed induction generator(DFIG) based wind power generation systems,and the vector control of DFIG needs accurate signal of rotor position for coordinate transformation,in general,this signal is acquired by incremental photoelectric encoder.In view of unfavorable operation environment of wind power generation system,the pulse signals in encoder,especially the Z pulse signal,are susceptible to be interfered,and it makes the deviation in the measured rotor angle.By use of eigenvalue analysis,the influence of measured rotor angle on system stability is researched,and the simulation and experiments of DFIG with capacity of 1.5MW are performed.Simulation and experimental results show that due to the deviation of measured rotor angle the serious consequences,such as system instability and so on,are possible to occur in wind power generation system.
What problem does this paper attempt to address?