APPLICATION OF IRON-CARBON MICRO-ELECTROLYSIS INTEGRATED PROCESS IN TREATMENT OF GARLIC WASTEWATER

Tang Chengli,Chang Qing,Yan Wei
2012-01-01
Environmental engineering
Abstract:A special treatment process of integrated coagulation-iron-carbon micro-electrolysis-reinforced electrolysis process was employed to treat garlic wastewater with iron-carbon micro-electrolysis as the core technology.Effect of micro-electrolysis operation parameters on the COD removal rate was studied,including aeration,pH of the water,reaction time,iron-carbon mass ratio and iron-water mass ratio.Experimental results showed that after being pretreated with integrated process,the pungent aromatic smell of garlic wastewater was totally eliminated,the removal rate of turbidity was up to 100%,the COD value of garlic wastewater was reduced from 13050 mg/L to 878 mg/L with the total COD removal rate of 93.3%.And the ratio of BOD5/COD(B/C) was improved from 0.10 to 0.46.The biodegradability of wastewater was significantly improved.
What problem does this paper attempt to address?