Abstract:A four-compartment anaerobic baffled reactor(ABR) was used to treat oilfield wastewater containing partially hydrolyzed polyacrylamide(HPAM) at room temperature.Inoculums digested sludge was taken from a wastewater treatment plant in Qingdao.During the anaerobic treatment,the hydraulic retention time(HRT) decreased from 24h to 6h as the ABR fed with organic load rate(OLR) of 1,1.3,2 and 4kg CODCr/ m3.d,respectively.When HRT was 24h,average chemical oxygen demand(CODCr) and HPAM removal rate could reach up to 0.945 and 0.662,respectively.The value of pH,CODCr and HPAM removal decreased sharply when HRT declined to 6h.The volatile fatty acids accumulated rapidly in effluent.Based on the IR analysis of HPAM,it could be inferred that microbial consortium with a better HPAM-utilizing ability could be enriched in the ABR reactor.Furthermore,the microorganism could use HPAM as the sole source of carbon and nitrogen nutrition for their growth.