DNA MODIFIED CARBON PASTE ELECTRODE FOR THE DETECTION OF 6-MERCAPTOPURINE

Jun-Jie Zhu,Kai Gu,Jin-Zhong Xu,Hong-Yuan Chen
DOI: https://doi.org/10.1081/AL-100102577
2007-01-01
Analytical Letters
Abstract:A new method for the preparation of a DNA modified carbon paste electrode has been developed and its electrochemical behavior has been investigated. It is found that 6-mercapto-purine(B-MP) can be accumulated onto this electrode surface. This electrode has been used for the determination of 6-MP by differential pulse voltammetry; The linear range is between 5.0 x 10(-6) and 8.0 x 10(-5) mol/L, with a detection limit of 2.0 x 10(-6) mol/L. The relative standard deviation is 3.6% for eight successive determinations of 2.0 x 10(-5) mol/L 6-MP. The determination of 6-MP tablets was also carried out and satisfactory results have been obtained.
What problem does this paper attempt to address?