Study on the Dissolution of Ondansetron Hydrochloride Tablets of Different Manufacturers

张关敏,赵冰清,张艳华
2012-01-01
Abstract:Objective To investigate the dissolution of ondansetron hydrochloride tablets of 3 different manufacturers.Methods The dissolution test was carried out by paddle method inChinese Pharmacopoeia 2010 edition,and the absorbance of ondansetron hydrochloride solution was measured by UV spectrometry,then the concentration of ondansetron hydrochloride was calculated according to the absorbance of standard reference.Cumulative dissolution percentage as well as dissolution parameters was calculated using Excel software.Results The dissolution performance of ondansetron hydrochloride tablets in 3 different manufacturers all reached the Chinese Pharmacopoeia requirements,but there are some differences between each brand.Conclusion Attentions should be paid in the clinical use of ondansetron hydrochloride tablets because of the differences dissolution patterns between different manufacturers.
What problem does this paper attempt to address?