The biological safety evaluation of Ti-Zr-Nb-Sn alloy for dental restoration
HU Xin,WEI Qiang,LI Chang-yi,DENG Jia-yin,LIU Shuang,ZHU Dong-wang,ZHANG Lian-Yun
DOI: https://doi.org/10.3969/j.issn.1009-3761.2010.01.013
2010-01-01
Abstract:Objective:To evaluate the biological safety of Ti-Zr-Nb-Sn alloy for dental restoration. Method:According to the GB/T16886.5-2003, GB/T16886.10-2005, YY-T0279-1995, YY-T0127.2-1993, the samples were prepared and tested with the cytotoxicity test, guinea pig maximization test (GPMT), oral mucous membrane irritation test and acute general toxicity test. Result: The relative proliferation rates of Ti-Zr-Nb-Sn alloy was 124% and the level of cytotoxicity was grade 0. Skin sensitization experiment showed all the tested parts of cavies, which were adhered to the Ti-Zr-Nb-Sn alloy, did not have erythema and edema reactions after 24 and 48 hours, and the reaction integral was 0. According to the grading stan-dards of skin sensitization experiment, Ti-Zr-Nb-Sn alloy did not have apparent potential sensitization to cavy. The result of oral mucous irritation test showed that all samples had no mucous membrane irritation. The result of acute general toxicity test showed that all samples had no acute general toxicity. Conclusion: These data indicated that Ti-12.5Zr-3Nb-2.5Sn alloy, as a dental restoration material, had the good biological safety properties.