Efficacy of Disinfection of Public Contact Surface on Dental Chair Unit

刘翠梅,胡凯,班海群,丁建芬,蔡志刚
2012-01-01
Abstract:OBJECTIVE To observe the efficacy of Caviwipes in the cleaning and disinfection of public contact surface of dental chair unit.METHODS The light handle and pipeline connections of dental chair unit were cleaned and disinfected by Caviwipes disinfectant wipes.TPC semi-quantitative bacterial culture slides and ATP bioluminescence assay detector were used to measure the bacterial counts and relative light unit(RLU)before and after disinfecting.RESULTS There was statistically significant difference in the bacterial counts and RLU before and after the disinfection of the light handle and pipeline connections of dental chair unit(P0.01).As compared with bacterial counts,the difference between the two parts were statistically significant(P0.05).The bacterial counts interquartiles of the light handle ranged between 1 CFU/cm2 and 45 CFU/cm2,the pipeline connections between 1 CFU/cm2 and 5 CFU/cm2.The bacterial colony counts quartiles of the two parts were both 0 after the disinfection,the difference in the ATP value between the two parts was not statistically significant before the disinfection.CONCLUSION Caviwipes disinfectant wipes have remarkable efficacy in the disinfection of public contact surface of the dental chair unit.