The Detection of Iron-containing Lesions Using MRI T2*WI after Spontaneous Intracerebral Hemorrhage in Animal Experiments

HU Shu-Kun,WU Gang,CHANG Chuan,HUANG Feng-Ping
DOI: https://doi.org/10.3969/j.issn.1008-0678.2012.01.006
2012-01-01
Abstract:Aim: To detect the iron-containing lesions using MRI GRE-T2*WI after spontaneous intracerebral hemorrhage(SICH) in animal experiments.Methods: Rats received an injection of autologous blood(group A 10 μL;group B 50 μL and group C 100 μL),1,3,7,14 and 30 days after the operation,rats were given MRI T2WI and T2*WI scans around the needle area,MRI were recorded and analyzed by using Image J.Results: MR T2*WI images of iron lesion were significantly more clear than T2WI.In group A and B,the lesion volume in T2*WI images was larger than T2WI images 7 and 14 days after SICH(P<0.05).In group C,the lesion volume in T2*WI images was larger than T2WI images 7,14 and 30 days after SICH(P<0.05).Conclusion: T2*WI are more clear and sensitive than T2WI in the detection of iron lesion after SICH.
What problem does this paper attempt to address?