Advanced treatment of vitamin C wastewater by electrolytic oxidation and AF-MBBR integrated reactor

WANG Zhao,HU Xiao-bing,XU Ke,REN Hong-qiang,ZHENG Qiao-geng
2011-01-01
Abstract:Advanced treatment of the effluent from anaerobic-aerobic biological treatment of vitamin C wastewater with electrolytic oxidation coupled with AF-MBBR integrated reactor was studied.Electrolytic oxidation was effective for decolorization,and the optimal operation conditions were as following: pH of 4,current density of 50 mA/cm2,electrolysis time of 15 min,and the distance of electrodes of 25 mm.Under these conditions,the TOC and chroma of effluents were 97.6~123.2mg/L and 135~155 times respectively.The ratio of BOD5/COD increased from less than 0.1 to about 0.24.Upon pretreatment,the effluent was further treated through AF-MBBR integrated reactor.The TOC,chroma and NH4+-N decreased to 57.18mg/L,60 times and 2.55mg/L respectively,which primarily discharge met the standards(GB 21903-2008) for fermentation pharmaceutical industry,verifying the feasibility of the combined treatment process for advanced treatment of vitamin C wastewater.The optimum HRT of the integrated reactor was 10h.The addition of 100 mg/L glucose substantially enhanced denitrification and more than 78.1% of TN was removed.It showed that glucose could be used as the appropriate carbon resource for denitrification for advanced treatment of vitamin C wastewater.In addition,ultraviolet and infrared analysis showed that the chromophore was mainly from the carbonyl groups,which could be broken by the electrolytic oxidation and the AF-MBBR biological treatment.