Development of Adjustable Sculpting Apparatus for Dental Crown Shape Specimen

JIN Hai-li,JIA Jun,DENG Zai-xi,LIU Geng,DUAN Yuan-yuan,ZHOU Jian-xue
DOI: https://doi.org/10.3969/j.issn.1003-8868.2012.01.010
2012-01-01
Abstract:Objective To design adjustable sculpting apparatus for dental crown shape specimen with high sensitivity and convenience in order to exactly control the accurateness and uniformness of each layer structure size of dental crown shape specimen.Methods With AUTO CAD software analyse,the sculpting apparatus to control the thickness for wax pattern of core crown and veneer specimen was developed.Three groups wax type specimens with the thickness of 0.75,1.00 and 1.20mm were made respectively.The wax pattern was cut vertically from the occlusal surface,the thickness of the occlusal surfaces and axial wall could be measured randomly.Results The thickness measurement error of the wax pattern was 0.01 mm,there was no significant difference between the thickness of occlusal surfaces and axial wall in the same group(P0.05).Conclusion Design of the sculpting apparatus is rational and scientific,the results of measurement are accurate and reliable,specimen processing is repeatable,and the practical size of occlusal surface thickness and axial wall thickness are in accord with the theory.The precision of the sculpting apparatus satisfies experiment testing requirements of dental restoration material.
What problem does this paper attempt to address?