Preliminary Research on Dual Phases Angiography of Pancreas with Multidector-Row Computed Tomography

郭献忠,刘再毅,严志汉,余苔痕,叶彩儿
DOI: https://doi.org/10.3969/j.issn.1000-2138.2007.02.018
2007-01-01
Abstract:Objective:To discuss the optimal scanning parameters of MDCTA of pancreas with multidector-row CT. Materials and Methods: Dual-phase CTA using a Siemens Sensation 16 scanner was performed in 40 cases meeting the including and excluding criteria. Acquisition of arterial and portal phase scan was obtained with bolus-tracking and test-bolus techniques, respectively. Pancreatic vessels were evaluated by axial images, MIP and VR. Results: The indirect pancreatic feeding arteries, PV, SMV, SV, RGEV were all seen in each technique. In MIP, VR, visualization rates of PSPDA were 91.5% and 67.5% respectively,ASPDA, 92.5% and 80%; IDPA, 67.5% and 57.5%; RSCV, 87.5% and 80%; PSPDV, 65% and 40%; ASPDV, 62.5% and 45%. Conclusion: Conspicuity of pancre-atic CTA can be gained using MDCT with combination of preparation prior to scanning, optimal slice thickness and scanning time, enough dosage and inject rate of contrast materials.
What problem does this paper attempt to address?