A Study on the Effect of Lidocaine-Assisted Non-Coring Needle Placement Using Painless Encircling Puncture in Children with Totally Implantable Venous Access Device
DOI: https://doi.org/10.2147/jmdh.s459786
2024-05-16
Journal of Multidisciplinary Healthcare
Abstract:Xiu-Li Xiao, 1, &ast Qian-Xue Yang, 2, &ast Hui-Zhong Niu, 1 Li-Jing Li, 1 Jian-Lei Geng, 1 Dan Zhao, 1 Hui Ren, 1 Pan-Pan Yang 1 1 Department of General Surgery I, Hebei Children's Hospital, Shijiazhaung, 050000, People's Republic of China; 2 Department of Operating Room, Hebei Children's Hospital, Shijiazhaung, 050000, People's Republic of China &astThese authors contributed equally to this work Correspondence: Xiu-Li Xiao, Department of General Surgery I, Hebei Children's Hospital, No. 133 Jianhuanan Street, Shijiazhuang, Yuhua District, 050000, People's Republic of China, Tel +86 0311 8591 1321, Email Purpose: This study aimed to investigate the maintenance effect of two puncture methods using non-coring needles in children with totally implantable venous access device (TIVAD). Methods: The 110 children who received TIVAD implantation for short bowel syndrome and solid tumors in our department from 2021.12 to 2022.12 were selected as the study subjects. Blinded method was used and divided into experimental group and control group according to random number table The experimental group underwent painless surround puncture method to place the needles and compound lidocaine ointment for topical anesthesia, while the control group underwent traditional puncture method to complete this operation. The effects of the two puncture methods on pain, catheter seal fluid volume, and catheter occlusion rate were evaluated using the Facial Pain Scale Revised, Behavioral Assessment Scale, and in vitro digital subtraction angiography test. Results: In the control group, the degree of puncture pain was mild in 5 patients, moderate in 19 patients, and severe in 28 patients; the amount of catheter sealing solution was 9.32 ± 1.32 mL, and the catheter occlusion rate was 25.00%. In the experimental group, the degree of puncture pain was mild in 16 patients, moderate in 22 patients, and severe in 16 patients; the amount of sealing solution was 7.66 ± 1.08 mL, and the blocking rate was 9.26%. The total pain score in the experimental group was lower than that in the control group (5.23± 6.17 VS 7.89± 2.38). The difference between the two groups had statistical significance (P < 0.05). Conclusion: The use of the painless surround puncture method can effectively reduce the pain experienced by children during puncture, decrease the volume of catheter sealing fluid, reduce the rate of catheter blockage, provide a valuable basis for enhancing the maintenance effect of TIVAD in clinical practice for children. Keywords: catheter blockage rate, catheter sealing fluid volume, pain, puncture method, totally implantable venous access device In recent years, the number of children with short bowel syndrome and solid tumors has been increasing, which has become two major killers threatening children's health. The 2016 edition of the Chinese Consensus on the Diagnosis and Treatment of Short Bowel Syndrome proposes that children with short bowel syndrome need long-term parenteral nutritional support interventions due to the fact that most of the small bowel has been resected and absent, which makes the absorption capacity of the small bowel limited. And the treatment method for children with solid tumors is mostly chemotherapy. During the chemotherapy process, multiple punctures of the patient's veins are required, and the extravasation of chemotherapy drugs can cause complications such as skin necrosis. To ensure the smooth completion of parenteral nutrition and chemotherapy treatment, effective venous channels need to be established. 1–3 Totally implantable venous access device (TIVAD) is a kind of closed venous infusion device that can be placed into the subcutaneous and left in the body for a long period of time, which consists of a pump body and a catheter that can be visualized, and it can prevent the damage of irritating drugs to the vein and reduce the risk of drug extravasation and chemotherapy by the local high flow rate and high flow rate of the blood that can rapidly dilute and disperse the drugs. It can effectively prevent the damage of irritating drugs to the vein and reduce the complications such as drug extravasation and tissue necrosis, and can be used for infusion of various drugs, blood transfusion and blood sample collection, etc. 4 The configuration of TIVADs, with their pump body and catheter, embodies principles of fluid mechanics crucial for optimal drug delivery. By facilitating rapid dilution and dispersion of drugs within the bloodstream, these devices mitigate the risks associated with vein damage and drug extravasation. However, the use of TIVAD requires no -Abstract Truncated-
health care sciences & services