Determination of Polynuclear Aromatic Hydrocarbons(PAHs) in Environmental Samples by Capillary Electrophoresis.

XX Zhang,Y Yang,T Korenaga
DOI: https://doi.org/10.2116/analsci.13.supplement_235
IF: 1.967
1997-01-01
Analytical Sciences
Abstract:The polynuclear aromatic hydrocarbons(PAHs) were separated by capillary electrophoresis with uncoated fused silica capillary(50 mu m i.d., total length 50 cm, effective length 32 cm). A berate buffer solution containing sodium dodecyl sulfate, beta-cyclodextrin, and acetonitrile was utilized. The separation was monitored by a spectrophotometer at the wavelength of 220 nm. The detection limits of some PAHs were in the range of 0.1-2 mu g/mL. It is satisfactory to apply this method to the analysis of some PAHs in environmental samples.
What problem does this paper attempt to address?