MECHANISM OF DEGRADATION IN FLUIDIZED-PELLET-BED REACTOR WITH TWO STAGES

Li Kan,Wang Xiaochang,Wang Wendong,Li Zhongmin
DOI: https://doi.org/10.16796/j.cnki.1000-3770.2010.09.009
2010-01-01
Abstract:To estimate the degradation of contaminants in this system,it have been on research that are jar test and FPB with two stages' operation.The results show that,when COD of 300 mg·L-1 pumped into wastewater,it is limited to the removal of sodium acetate in wastewater for jar tests,and the coagulated part could be only 3.8 mg·L-1.Compared with jar tests,the removal of FPB with two stages' operation is much better that the average COD in the effluent is 31.0 mg·L-1.It could be further shown in the analysis of contaminants in the space distribution that the variation of contaminants in the system of FPB with two stages and the important influence of DO on the removal of soluble contaminants.As DO reduced from 8 mg·L-1 to 2 mg·L-1 in the primary column,most soluble sodium acetate could be removed and the average COD in the effluent could be 48.1 mg·L-1 in this part;and when 2.6 mg·L-1 DO have been used in the secondary column,soluble COD could be only removed for 20 mg·L-1.
What problem does this paper attempt to address?