Internal Stress Measurement for Dam of Hydropower Station Based on Vibrating Wire Sensors

ZHANG Guang-xin,WU Xiao-wen
DOI: https://doi.org/10.3969/j.issn.1673-7598.2011.08.007
2011-01-01
Abstract:Combined with the characteristics of vibrating wire sensors,centralizing on microcontroller MSC1210,this paper got the frequency from the sensor by equal precision measurement and compensated temperature with software.Based on which,the paper realized a portable,low-cost and high precision device to measure the stress in the dam of hydropower station.The test result shows that water level resolution of this device is up to 0.00002m,and the maximum absolute error between experiment and actual value of water level is less than 0.005m,which meets the demand in practical use completely.
What problem does this paper attempt to address?