Degradation of Formaldehyde in Dielectric Barrier Discharge Plasma Reactor

Chen Li,Dai Wen,Yan Zong-cheng,Wang Hong-lin,Cheng Bei-bei
DOI: https://doi.org/10.3321/j.issn:1000-565x.2008.12.010
2008-01-01
Abstract:This paper deals with the energy consumptions for the formaldehyde degradation in two dielectric barrier discharge(DBD) plasma reactors respectively with tube and flat plate types.It aims to reveal the influences of discharging voltage,initial formaldehyde mass concentration and residence time on the degradation rate of formaldehyde.Experimental results indicate that(1) the energy consumption in the flat-plate reactor(12.8 Woh/m3) is far below that of the tube reactor(55.0 Woh/m3);(2) the degradation rates of formaldehyde in both the tube and the flat-plate reactors greatly increase with the discharging voltage,then the increase degrees become low at the voltages of 11 kV and 18 kV,respectively;and(3) the degradation rate at first increases with the initial formaldehyde mass concentration and then decreases,but it continuously increases with the extension of the resistance time.