Treatment of Refractory Anthraquinone Dyeing Wastewater by Micro-Electrolysis and Fenton Oxidation Process
YANG Jian,WU Yun-tao,XING Mei-yan
DOI: https://doi.org/10.3321/j.issn:0253-374x.2005.12.016
2005-01-01
Abstract:We have studied the treatment of anthraquinone dyeing wastewater,a refractory organic wastewater characterized with COD 750~850 mg·L~(-1),400~500 units chromaticity and ρ(BOD_5)/(ρ(COD)) ratios of 0.10~0.13,by micro-electrolysis Fenton reagent oxidation process.The pathways of refractory organics conversion and treatment efficiency influenced by various reaction conditions and process parameters were investigated too.The results indicated that when the ratio of Fe and C volume in the electrolysis column was 1∶1,hydraulic reacting time(HRT) was 2.0 h,the dosages of Al_2(SO_4)_3 and PAM were 150 mg·L~(-1) and 3 mg·L~(-1),respectively,as well as the sedimentation time was 30 min at pH=4,the effluent showed ρ(COD)208~342 mg·L~(-1),ρ(BOD_5)17~30 mg·L~(-1),chromaticity 15~40 units,respectively,through micro-electrolysis and chemical coagulation process.Fenton-oxidation process taken as subsequent process showed that when the dosages of FeSO_4 and H_2O_2 were 200 mg·L~(-1) and 100 mg·L~(-1),respectively,as well as the reacting time was 30 min at pH=5,ρ(COD),ρ(BOD_5)and chromaticity of effluent were below 50 mg·L~(-1),10 mg·L~(-1) and 20(units),respectively.