A Comparative Study of the Application of 1 000 Hz and 226 Hz Tympanometry in Normal Infants of 0~36 Months

Wang Shufen,Chen Ping,Wang Zhinan,Huang Fang
DOI: https://doi.org/10.3969/j.issn.1006-7299.2010.06.010
2010-01-01
Abstract:Objective To investigate the application of 1 000 Hz and 226 Hz tympanometry in infants of 36 months younger.Methods The tympanograms were recorded from 648 infants with a MADSEN OTOFLE100 Middle-Ear analyzer.The infants were divided into four groups:Group 1 (0~3 months),Group 2 (3~6 months),Group 3 (6~9 months),and Group4 (9~36 months ).The data for each group were statistically analyzed.Results Using 226 Hz tympanometry ,66.82%(147/220) were abnormal in Group 1,33.49%(33/218) in Group 2,34.76%(73/210) in Group 3 and 1.85%(12/648) in Group 4.Using 1 000 ympanometry,4.09%(9/220) were abnormal in Group 1,11.01%(24/218) in Group 2,32.86%(69/210) in Group 3 and 57.10%(370/648) in Group 4.Conclusion In 0~6 month's infants,1 000 Hz tympanometry was an sensitive diagnostic test to the middle ear dysfunction,while 226 Hz tympanometry failed to be so.The combination of 1 000 Hz and 226 Hz tympanometry will be suitable in the diagnosis of the middle ear function in 6~9 month infants and 226 Hz tympanometry can objectively assess middle ear function in 9~36 month infants.