Degradation of aqueous bromobenzene by ultrasound: influences of operative parameters and environmental factors

Guang-ming Zhang,Xi-hui Zhang,Min-Sheng WU
DOI: https://doi.org/10.3969/j.issn.1000-310X.2005.01.010
IF: 3.614
2005-01-01
Applied Acoustics
Abstract:The kinetics of de-halogenation during bromobenzene degradation by ultrasound are studied in this paper. Affecting factors studied include important operative parameters such as the acoustic intensity and saturating gases and environmental impurities such as suspended solids and impurities found in surface water. The results show that ultrasound can degrade aqueous bromobenzene efficiently, with the 1st order rate constant being 0.044/min at 20kHz, 7.5W/cm2 with 58% dehalogenation. Higher sound intensity leads to more rapid degradation. Saturation with oxygen or argon strengths sonication more compared to that saturated with air. The reaction is not influenced by the surface water impurities, nm size particles and inorganic particles, but is slowed down by organic suspended particles.
What problem does this paper attempt to address?