Fabrication and its application of Hb/Fe3O4/CILE

上官小东,王燕,汤宏胜,郑建斌
DOI: https://doi.org/10.13595/j.cnki.issn1000-0720.2013.0231
2013-01-01
Abstract:Based on ionic liquid carbon paste electrode(CILE),Hb /Fe3O4 / CILE modified electrode was prepared by casting and static adsorption.The direct electrochemistry and electrocatalysis of Hb were investigated on the Hb / Fe3O4 / CILE,and a new H2O2 determination method was established by chronoamperometry.The experimental results showed that a pair of quasi-reversible redox peaks of Hb was exhibited on the modified electrode.The average surface coverage of hemoglobin on the Hb / Fe3O4 / CILE,the electronic transfer rate constant,and the apparent Michaelis-Menten constant were 2.65 × 10-9mol / cm2,1.35/s and 1.59 × 10-5 mol / L,respectively.The proposed electrode exhibited good electrocatalysis towards H2O2,and the catalytic current was linear with concentration of H2O2 in the range of 1.0 × 10-6~ 4.0 × 10-5mol / L(r = 0.9976) with a detection limit of 3.0 × 10-7mol / L(S / N = 3).
What problem does this paper attempt to address?