Abstract:Objective To investigate the causes and treatment methods of complications caused by the tissue expander used in the trunk. Methods We reviewed retrospectively our patients with tissue expanders in the trunk from October 2002 to October 2005, and summarized the reasons and the treatment methods of the complications. Results A total of 229 expanders were used in 98 patients. The complications included 17 instances of expander exposures, 12 cases in which the expander became unexpanded, 9 haematomas and 5 infections. All complications were healed after surgical removal of the expander and control of the infection. Conclusion The complications caused by the tissue expander used in trunk were very common. Appropriate operative technique, the choice of surgical methods, careful observation and immediate treatment were important for preventing and reducing the complications.