Effect of Temperature Gradient on Thermally Stimulated Depolarization Current Measurement

纪哲强,吴建东,兰莉,李喆,尹毅
DOI: https://doi.org/10.13336/j.1003-6520.hve.2011.10.019
2011-01-01
Abstract:Thermally stimulated depolarization current(TSDC)was used to determine charge transportation and trap levels in dielectric. To investigate and improve TSDC measuring system, the TSDCs of polyester (PET) film cooperating with two types of electrodes, as well as temperature gradient in both types of electrodes, were measured. The influence of temperature gradient on TSDC was analyzed. Results show that an asymmetric electrode structure can result in a non-uniform heating condition of the specimen, and a significant temperature gradient in specimen. It is found that a complete TSDC curve consists of two distinct peaks named a and ρ peaks, respectively, with the asymmetric electrode structure. It is also found that the temperature gradient has a greater impact on ρ peak which is caused by trapped charge in PET films, while it has less impact on the position of a peak which is caused by dipole. Under certain temperature gradient, the ρ peak will move forward to a lower temperature. However, the position of a peak does not change obviously. It is even possible that the trap peak will disappear when polarization temperature is excessively high, which will influence the resolution and reliability of TSDC measuring result.
What problem does this paper attempt to address?