The impact of BIS and AAI attenuate depth of anesthesia on the stress response

LI Chuanyao,KANG Fang,MA Jun,WANG Ruiting
DOI: https://doi.org/10.3969/J.issn.1672-6790.2013.04.003
2013-01-01
Abstract:Objective To evaluate the impact of BIS and AAI attenuate the depth of anesthesia on the stress response in general anesthesia.Methods Forty ASA Ⅰor Ⅱ adult patients underwent gastrectomy surgery using total intravenous anesthesia were randomly assigned to two groups,the control group(C) and the the monitoring group(M).In group C,the depth of anesthesia was to keep blood pressure and heart rate in no more than ± 20% of their basic value.And in group M,the aim was to maintain the AAI 15 ~ 30 and BIS 40 ~ 55.MAP,HR,SpO2,the BIS and AAI were recorded on several points.The blood glucose and cortisol were detected at the same time.The OAA / S scale score and intraoperative awareness were assessed after surgery.Results The MAP and HR of the control group rose on time of skin incision(P < 0.05).The BIS and AAI in group C were higher than those in group M during the operation(P < 0.05).The blood glucose and cortisol of group C were higher than those in group M during the operation(P <0.05).The recovery time of group M were shorter than group C.There was one patient in group C occurred intraoperative awareness.Conclusions Attenuating depth of anesthesia according to BIS and AAI could shorten the recovery time,avoid intraoperative awareness,reduce the excessive stress response and improve the quality of anesthesia.
What problem does this paper attempt to address?