Abstract:Using transformer distributed parameters as component in LLC resonant tank could improve the performance and reliability of high voltage converter.It is essential to extract high voltage transformer distributed parameters.Based on the equivalent circuit model of transformer,it is analyzed that the measuring method of transformer distributed parameters based on the Bode plot of impedance and gain frequency response.The frequency response of the designed high-voltage transformer is measured.It is computed the parameters include magnetizing inductance,leakage inductance,winding capacitor,DCR(Directed Connected Resistance) and Core loss Resistor.The SPICE simulation upon computed result verifies the validity of the method.