Shear strength of interior steel reinforced high strength concrete beam-column joints

Jia Jinqing,Zhu Weiqing,Wang Jizhong
2013-01-01
Abstract:Twelve interior steel reinforced high strength concrete(SRHC) beam-column joints were tested under lateral cyclic force and constant axial load.Based on experimental results and relevant literatures,it is found that axial pressure coefficient,volumetric ratio of stirrups and structural steel are the main factors affecting the shear strength of joints.A model was developed to determine the shear strength of interior SRHC beam-column joints considering the main factors,with the contributions of steel web,inner and outer concrete diagonal struts and truss mechanism to the shear strength of joints considered.Three groups of tests,including the one designed in this study and the other two,were selected for the comparison study.The shear bearing capacities of these joints were evaluated by the model and code formulas,respectively.Comparison study shows that Code JGJ 138—2001 may reasonably predict the shear strength of SRC column-RC beam joints made by normal strength concrete,but may overestimate the strength of SRC column-SRC beam joints made by high strength concrete.While Code YB 9082—2006 underestimates the shear strength of joints made by concrete with various strength.Comparatively,the proposed model may predict the shear strength of joints made by concrete with various strength reasonably,and hence it is suitable for the shear design of interior SRHC beam-column joints.
What problem does this paper attempt to address?