Encapsulation of recombinant human endostatin using a W/O/O phase separation method

XU Xiang-yang,LI Ling,HUA Su,HU Yi-qiao
2010-01-01
Abstract:Objective:To prepare recombinant human endostatin(Endostar) loaded sustained release microspheres and to evaluate the characterization and release behavior of microspheres.Methods:Endostar loaded microspheres were prepared by W/O/O phase separation method.The characters of microspheres,such as drug loading,size and burst release were evaluated.The in vitro release behavior was studied and the degradation was observed.The integrity of Endostar released from microsphere was detected by SDS-PAGE.Results:The increase of the percent of glycolic acid led to increase the drug loading and release rate.By decreasing internal phase volume and increasing theoretical drug loading and the concentration of poly(D,L,lactic-co-glycolic acid)(PLGA),Endostar was easier to encapsulated into microspheres.Burst release decreased with increasing homogenization speed but increased with internal phase volume.The accumutive release rate could be increased to 65% at day 30 by increasing the proporation of glycolic acid in PLGA.The in vitro release of Endostar from the microspheres dependented on diffusion of drug through the matrix in the early stage and degradation of PLGA in the later stage.The SDS-PAGE study indicated that Endostar encapsulated did not show any aggregation.Conclusion:Endostar can be encapsulated in microspheres to yield a sustained release when using PLGA polymers as carrier materials.