Simultaneous determination of 18 benzodiazepines in pork by solid phase extraction and liquid chromatography-tandem mass spectrometry

Yan Ai-hua,Li Xian-liang,Xi Cun-xian,Zhang Lei,Xia Shuang,Wang Guo-min,Tang Bo-bin,Mu Zhao-de
DOI: https://doi.org/10.13995/j.cnki.11-1802/ts.2013.04.004
2013-01-01
Abstract:A sensitive liquid chromatography-tandem mass spectrometric(LC-MS/MS) method has been developed for simultaneous determination of 18 benzodiazepines in pork sample.The sample was hydrolysised by enzyme in pH 5.2 ammonium acetate buffer followed by adjustment of pH value more than 9.5 with ammonium hydroxide.The benzodiazepines residues were extracted by aceticether-isopropol(5∶1,v/v),defatted by hexane and cleaned up by MCX solid phase extraction column.The analytes were detected by positive electrospray ionization tandem mass spectrometry in the multiple reaction monitoring(MRM) mode,and quantified by isotope internal standard method.Good linear correlations were found between the peak areas and concentration in 18 benzodiazepines in the range of 0.5-50.0 μg/L,the correlation coefficients were all above 0.9990.The limits of detection(LOD) of these 18 benzodiazepines were in the range of 0.01-0.13 μg/kg,limits of quantification(LOQ) were in the range of 0.04-0.45 μg/kg.The average recoveries of benzodiazepines were 76.0%-107.2%,at spiked levels of 1.0,2.0 and 5.0 μg/kg,the relative standard deviation(RSD) of the method was between 2.3% and 9.1%.