Influencing factor on circuit life span in critically ill patients with continuous renal replacement therapy

NI Hong-ying,XU Xiao,ZHU Hong-yang,SHENG Xiao-yan,JIN Ni,ZHANG Zhong-heng
DOI: https://doi.org/10.3877/cma.j.issn.1674-6880.2012.05.003
2012-01-01
Abstract:Objective To explore the influencing factor of circuit life span in critically ill patients with continuous renal replacement therapy (CRRT). Methods A total of 131 filters in 32 patients with CRRT were divided into group A (circuit life < 48 h, 106 filters) and group B (circuit life ≥ 48 h, 25 filters). The levels of serum albumin, hematocrit, platelet, plasma ionized calcium, pH value, activated partial thromboplastin time (APTT), prothrombin time (PT), dose of heparin and temperature were recorded and compared. The multivariate liner regress was used to analyze the correlation factor of circuit life ≥ 48 h. Results The levels of plasma ionized calcium, pH value and temperature in group B were much lower than those in group A (all P < 0.05). The multivariate liner regress analysis showed an association between the circuit life ≥ 48 h and plasma ionized calcium and pH value. Conclusion The plasma ionized calcium and pH value can effect circuit life ≥ 48 h in patients with CRRT.
What problem does this paper attempt to address?