Shaking table test of fault-crossing buried pipelines Ⅱ: test results

Zhang Zhichao,Wang Jinting,Xu Yanjie
DOI: https://doi.org/10.15951/j.tmgcxb.2011.12.008
2011-01-01
Abstract:A shaking table test for fault-crossing buried pipelines is implemented.The pipes are buried in a container which is filled with sandy soil and can simulate the movement of a strike-slip fault.The strain and deformation of the pipes and the pressure between pipe and soil are analyzed.The effects of the fault-pipe angle and the water in pipe are also investigated.According to the test results,the dynamic effect of the pipe-soil system is relatively unimportant and can be neglected,but the impact of the liquid in pipe cannot be always neglected.When fault cannot be avoided,the pipelines are better placed perpendicularly to the fault.The maximum strain always occurs at some distance away from the fault.The dynamic pipe-soil interaction may significantly impact the pipes.
What problem does this paper attempt to address?