[Experimental Study of Preventing Postoperative Stenosis by Modifying Artificial Esophagus in Dogs].

Lan-Jun Zhang,Tie-Hua Rong,Guo-Liang Xu,Xiao-Dong Su,Fa-Chao Zhi,Xiao-Ming Guo,Peng-Yuan Zhang
DOI: https://doi.org/10.3760/cma.j.issn.1671-0274.2001.03.007
2001-01-01
Abstract:OBJECTIVE To observe the effect of the modified artificial esophagus on postoperative stenosis in dogs. METHODS The models of defected esophagus were established in dogs. The double-layered membrane tube (modifying type) was implanted in the test group (n = 10) and the esophageal stent was further inserted when the stenosis occurred. The single pattern tube (original type) was transplanted to the control group (n = 30). The dilation treatment was performed to relieve the postoperative stenosis; alternatively, the esophageal stent was implanted in the unsuccessful dogs. RESULTS The average artificial esophagus removal time was 19.10 days in the test group, which was significantly lower than 39.07 days in the control group (t = 15.6, P = 0.000). No obstruction after removal was observed in the experimental group. The incidence of postoperative stenosis had no significant difference between these two groups. CONCLUSION The double-layered membrane tube can make the tube removal safer by shortening the removal time.