Contrast monitoring analysis of atmospheric particulate matter concentration of Chongqing urban area in spring

Li Li,Xiang Hong,Yu Jiayan,Zhou Qian,Qin Hongyu,Zhai Chongzhi
2012-01-01
Abstract:Through a contrast monitoring experiment between manual sampling and automatic instrument,data of atmospheric particulate matter(PM10 and PM2.5) at the atmosphere observation super station of Chongqing in spring of 2012 were obtained.The consistency between automatic monitoring and manual monitoring was made and its deviation was discussed.Then,concentration relation of PM2.5 and PM10 was analyzed.The results showed that when MP101M automatic particle monitor was used to monitor PM10 concentration,system error was on the high side and negatively initial precision deviation existed.While it was used to monitor PM2.5 concentration,system error was within the scope of the permit,but much negatively initial precision deviation was showed.The changing trend of PM10 and PM2.5 data had a very high consistency between manual and automatic monitoring.By manual monitoring,PM2.5 concentration accounted for 56.5%~90.4% of PM10,average proportion was(73.8±7.4)%.
What problem does this paper attempt to address?