Abstract:The separation of hydrogen isotope gases was studied on a single-column pressure swing adsorption apparatus with molecular sieve VP800-5 as adsorbent at the liquid nitrogen temperature. The effects of gas flow rate, operating pressure and length of the adsorption bed on separation efficiency were investigated. The results show that the separation factor of hydrogen and deuterium mixture can be up to 1.63 at total pressure of 0.4 MPa, flow rate of 129.79 cm3·min-1 and with the adsorption bed length of 1.0 m. However, the ratios of equilibrium adsorption capacity between deuterium and hydrogen are only 1.14 and 1.11 at 0.0139 MPa and 0.0175 MPa, respectively. Based on the results of equilibrium adsorption, dynamic adsorption and separation, it shows that the hydrogen isotopes can be separated effectively by the adsorption method at low temperature, which mainly depends on the significant difference of kinetic adsorption rate between hydrogen isotopes. Moreover, a dynamic model was proposed to simulate the adsorption process of hydrogen and deuterium separation, and the simulation results agree well with the experimental results.