Quantitative Analysis of Electromagnetic Force of High-Speed Solenoid Valve for Electron-Controlled Unit Pump

范立云,高明春,马修真,石勇,孙军
DOI: https://doi.org/10.13949/j.cnki.nrjgc.2013.01.012
2013-01-01
Abstract:A 3-D finite element model for high-speed solenoid valve was established in Ansoft environment and validated by comparing to experiment results.The max.deviation of electromagnetic force is within 9%.The influence of key parameters affecting electromagnetic force,such as pole length,coil turns,coil position,armature thickness,damping hole position,damping holes size,etc.was studied in the whole operating conditions by using the model.Through quantitative analysis,their percentage rates and changing rule were obtained.The influence percentage of pole length is 0.03%~1.26%,coil turns 20.6%~80.9%,coil position 1.9%~15.5%,armature thickness 11.5%~55.6%,damping holes position 3.5%~8.6%,damping holes size 1.6%~7.8%.Among them,coil turns and armature thickness are the two significant key parameters.
What problem does this paper attempt to address?